![ANCA Motion AMD2000 3A Скачать руководство пользователя страница 11](http://html.mh-extra.com/html/anca-motion/amd2000-3a/amd2000-3a_user-manual_2940728011.webp)
Safety
ANCA Motion
DS619-0-00-0019 - Rev 0
11
1
Never attempt cleaning or inspection during machine operation.
Only suitably qualified personnel should install, operate, repair and/or replace this equipment.
Be aware of the closest First Aid station.
Ensure all external wiring is clearly labelled. This will assist you and your colleagues in
identifying possible electrical safety hazards.
Clean or inspect the equipment only after isolating all power sources.
Use cables with the minimum cross sectional area as recommended or greater.
Install cables according to local legislation and regulations as applicable.
Insulation resistance testers (
sometimes known as a ‘megger’ or hi-pot tester) are not to be used
on the drive, as a false resistance reading and/or damage to the tester may result
If an inductor (choke) is placed between terminals P1 and P2 the choke shall be designed to
drop less than 5% of the line voltage.
1.2
Safe Start-Up and Operation
Please refer to sections
8 Installation Checklist
and section
9.6.12 Power-On Checks
for additional
checks that should be made to start up the AMD2000 series drives safely.