AMD2000 drives are suitable for use on supplies of installation category III and lower, according to IEC60664-1.
This means they may be connected permanently to the supply at its origin in a building, but for outdoor
installation closer to primary distribution supply (overhead cables etc.) additional over-voltage suppression
(transient voltage surge suppression) must be provided to reduce category IV to category III.
AC Supply
Unit
PIN SIGNAL
LC1
LC2
NC
L1
L2
L3
Control Voltage Single Phase Supply
Control Voltage Single Phase Supply
Not Connected
Single/Three Phase Supply
Single/Three Phase Supply
Single/Three Phase Supply
Figure 6-1 Mains Control and Power Supply Connector
L1
L2
3 phase only L3
AMD2000
Circuit Breaker /
Fuses
Isolation
Switch
AC Supply
105V - 265V line to line
(Optional)
Line Filter
LC1
LC2
NC
110V or 220V Single or 3 Phase Supply
P.E.
P.E.
Figure 6-2 Mains Supply System for Single Phase or 3 Phase Supply
L1
L2
L3
AMD2000
LC1
LC2
NC
110V or 220V Single Phase Supply
Circuit Breaker /
Fuses
Isolation
Switch
AC Supply
105V-265 line to neutral
(Optional)
Line Filter
P.E.
P.E.
Figure 6-3 Mains Supply System for Single Phase Supply