Product Overview
ANCA Motion
DS619-0-00-0019 - Rev 0
23
3
Inductor, Brake Resistor Connectors
3.6.12.6
To be able to use the drive without an external inductor
– a link rated at full drive current must
be
placed across P1 and P2 to avoid E0303 DC bus Voltage low alarm.
If an external brake resistor is not installed a link must be placed across P and D to be able to take
advantage of the internal brake resistor to dissipate regenerative energy.
For Additional Information refer to section
6.6 Power Supply Filters & 6.13 Brake/Regeneration
Resistor.
Control Power and DC Bus Power Connectors
3.6.12.7
LED Display and Control Panel
3.6.12.8
The AMD2000 series drives are fitted with a LED display and control panel as shown in the
following figure:
The characteristics of the display and control panel are detailed in the following table:
P1
P2
External inductor connection. P1 and P2 are in series with
DC BUS+ and might be connected to an external inductor
for extra energy storage and reducing voltage ripple.
P,C,D
Brake resistor connection
LC1
LC2
Single phase supply for control power
NC
Not Connected
L1
L2
L3
Single phase or three phase supply for DC bus