11
Encoder Adjusted Amplitude Low - Motor
E0215
Description
The magnitude of the adjusted signals for the motor analogue encoder is too low. Incorrect
gain and/or offset values have been configured.
Severity
Error
Encoder Adjusted Amplitude High - Motor
E0216
Description
The magnitude of the adjusted signals for the motor analogue encoder is too high. Incorrect
gain and/or offset values have been configured.
Severity
Error
Control Unit Synchronization Bit Toggle Missing
E0220
Description
This error indicates a problem with communications between the EtherCAT Master (eg. CNC)
and the drive. Please contact ANCA Motion for support.
Severity
Error
Distributed Clocks Error
E0221
Description
This error indicates a problem with communications between the EtherCAT Master (eg. CNC)
and the drive. Please contact ANCA Motion for support.
Severity
Error
Encoder Adjusted Amplitude Low - External
E0227
Description
The magnitude of the adjusted signals for the external analogue encoder is too low. Incorrect
gain and/or offset values have been configured.
Severity
Error
Encoder Adjusted Amplitude High - External
E0228
Description
The magnitude of the adjusted signals for the external analogue encoder is too high. Incorrect
gain and/or offset values have been configured.
Severity
Error
DC Bus Voltage High
E0302
Description
DC bus voltage in the power stage exceeded the hardware maximum limit. Possible causes
for this error are:
1. Regenerative load is outside the specification for the drive.
2. Mains supply voltage is too high.
3. Regeneration resistor or drive is faulty. Please contact ANCA Motion for support.
Severity
Error
DC Bus Voltage Low
E0303
Description
DC bus voltage in the power stage is below the hardware minimum limit. Possible causes for
this error are:
1. Mains supply is not connected.
2. Connector for external inductor, missing inductor or link across P1, P2.
3. Mains supply voltage is too low.
4. Power requirements for the application are outside the specification for the drive.
5. Drive is faulty.
Please contact ANCA Motion for support.
Severity
Error