![Amazone Cataya 3000 Super Скачать руководство пользователя страница 158](http://html1.mh-extra.com/html/amazone/cataya-3000-super/cataya-3000-super_operating-manual_2919712158.webp)
Settings
158
Cataya Super BAH0087-11 01.19
8.4.2
Calibrating the seed rate
Implements with AmaDrill 2 control terminal,
Implements with ISOBUS system
1. Prepare the implement for calibration, see
section " Calibrating the seed rate",
page 151.
2. Pre-calibrate the seed drill.
2.1 Pre-calibrate the seed drill according
to the "ISOBUS software" operating
manual.
Pre-calibration creates the same
conditions as when driving on the field
later on.
2.2 Empty the two-part collection bucket
(Fig. 191/1) into the seed hopper, put
together, and push it into the holder up
to the stop with the opening facing up.
Fig. 200
3. Calibrating the seed rate.
3.1 Calibrate the seed drill according to
the "ISOBUS software" operating
manual.
3.2 Fold out the bracket (Fig. 201/1) for
weighing the collected seed.
3.3 Weigh the content of the collection
bucket in the collapsible bucket.
Fig. 201
Check the scales to ensure the display
is accurate, taking the container weight
into consideration.
4. Repeat the calibration test until the desired
seed rate is achieved.
Содержание Cataya 3000 Super
Страница 27: ...General safety instructions Cataya Super BAH0087 11 01 19 27 Fig 3 Fig 4 ...
Страница 42: ...Product description 42 Cataya Super BAH0087 11 01 19 Fig 13 Cataya 3000 Super mounted on CombiDisc 3000 ...
Страница 107: ...Layout and function Cataya Super BAH0087 11 01 19 107 Fig 119 ...
Страница 247: ...Hydraulic diagram Cataya Super BAH0087 11 01 19 247 Fig 338 ...
Страница 249: ...Hydraulic diagram Cataya Super BAH0087 11 01 19 249 Fig 339 ...
Страница 250: ......
Страница 251: ......