10-52 ADS Manual
Problem
Velocity data seems erratic or exhibits poor quality.
Possible
Causes
Sensor’s transmit/receive surfaces may be dirty.
Sensor may be close to extending out of the flow.
Designated value for the maximum velocity parameter
may be too high, creating too broad of a range.
Transmit Frequency
setting may be incorrect.
Sensor may be faulty.
Processor board may be faulty.
Possible
Solutions
Clean the sensor’s transmit/receive surfaces.
Verify whether the flow depth exceeds the sensor
deadband at the same time and under the same
conditions as the erratic data. Rotate the sensor further
toward the center of the pipe if possible.
Change the
Transmit Frequency
. It should be set to
High
for optimal performance.
Reduce the maximum velocity in the device parameters
to narrow the range.
Check the sensor connections.
Contact your regional ADS representative.
Replace the sensor.
Replace the monitor if defective.
Problem
Velocity readings are abnormally high.
Possible
Causes
Sensor’s velocity transmit/receive surfaces may be
covered with silt or other debris.
Sensitivity
setting may be too high.
Sensor may be extending out of the flow.
Flow may be reversed or slower than (0.5 feet per
second (0.15 mps)
Possible
Solution
Check the site conditions, and relocate the sensor if
necessary.
Check the velocity parameters.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...