Maintenance and Troubleshooting 10-21
3.
Use needle-nose pliers to gently remove the black foam
packing material just inside the opening.
4.
Pour out the old desiccant beads from the dryer tube.
5.
Refill an equivalent amount of new desiccant beads into the
tube.
6.
Carefully replace the foam packing into the dryer tube.
7.
Replace and tighten the nut on the dryer tube.
8.
Secure the dryer tube to the monitor using cable ties, when
applicable.
9.
Use the
View
or
Read All
function in the
Qstart
software to
fire the sensor and verify that the sensor is working correctly.
Note:
Some desiccant may be reused following a special
process designed to remove the moisture from the beads.
Please consult the desiccant manufacturer for instructions
on performing this procedure, when applicable.
Replacing the SIM Card
monitors handle communications through an internal
modem that is supported by a replaceable SIM card that resides in
an enclosure on the monitor top. The SIM card typically requires
replacement only upon failure, which is rare, or when a change in
wireless carrier occurs.
The monitor must be deactivated before
replacing the SIM card!
Replace the SIM card (ADS p/n 507181 or customer-supplied) in
the modem in the following way:
1.
Deactivate the monitor through
Qstart
.
2.
Remove the monitor from the manhole, and place it in a dry,
clean location (i.e., an adequate distance away from the
manhole).
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...