
5-34
ADS Manual
15.
Slide the ring terminal from the ground wire onto the bolt (
with
the crimp barrel on the ring terminal facing the head of the
bolt
), and then slide the washer with the guide tabs and the
internal-tooth washer back onto the bolt. Make sure the ground
wire is exiting one of the sides of the washer that is not turned
up. The ring terminal should be seated
flat
against the washer
with the guide tabs.
Ground wire ring terminal from ground cable
16.
Slide the new retaining washer (from the external power
grounding kit) in between the monitor top and the canister,
positioning it so that it is properly aligned with the bolt hole.
17.
Insert the bolt with the stacked washers and ring terminal back
through both the hole in the monitor top and the new retaining
washer back until it contacts the threads in the hole on top of
the canister.
L
E
N
N
A
H
C
2
SENS
CPU
E
T
N
A
A
N
N
SENSORS
L
E
N
N
A
H
C
1
WAKE
+ EX T
R
w ww.adsenv.com
C
O
MM
PW
R
TM
STAT US
CONTAINS CELL XMTR
FCC ID: R17HE910
Ex ia IIB T3(152°C) Ga
Sira 09ATEX2027X
II 1 G
0518
MODEL: 8000 - FHK/FST-IM
Use only battery pack 8000-0043
IECEx SIR09.0020X
Ta = -20°C to +60°C
Ex ia IIB T3(152°C) Ga
Rev
DATE
MODEL: 8000 - FHK/FST-IM
Utilisez uniquement la batterie 8000-0043
Ta = -20°C to +60°C
CSA 2013 2671180
Ex ia IIB T3 (152°C)
S/N
See CONTROL DWG 8000BK0009
Voir SCHEMA DE CONTROLE
Use only battery pack 8000-0043
SIR 006
Hex bolt
Split Washer
Square Washer
Ground Wire Terminal
Washer with Guide Tabs
Internal-Tooth Washer
Retaining Washer
Bolt with ring terminal and washers inserted through monitor top and
secured with the retaining washer
18.
Tighten the bolt to approximately
30 inch-pounds
(
2.50 foot-
pounds/ 3.39 Nm
) to fully secure the ground connection facility
and the ground wire, as well as the top to the canister.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...