Sensor Installation and Connection
3-41
Quantity
Description
ADS P/N
1 as
needed
Sampler cable (
for flow proportional sampling
)
8000-0348-01
1 as
needed
Sampler cable (
for level activation sampling
)
8000-0348-02
4
M3 x 10mm flat head machine screws
507820
15
Plastic push mounts
1
3/8 in. - 16 thread. x 2.in. (10mm x 55mm x
1.5mm thread) stainless steel stud
1
3/8 in.
– 16 thread (10mm x 1.5mm thread)
stainless steel nut
As needed
3/8 in. (10mm) stainless washer
15
11-in. (5mm x 300mm) cable ties
25
4-in. (2mm x 100mm) cable ties
15
8-in. (4mm x 200mm) cable ties
15
¼-in. (7mm x 400mm) anchor cable ties
1
Model 8000-FST-IM-GL includes the 12-volt battery pack; Model 8000-FST-IM-
EP-GL (
for external power
) does not include the battery pack.
2
Pressure depth transducers (indicated by
-xx-
in the sample part number) are
available in Peak Combo Sensors and Surface Combo Sensors 0 – 5 psi (0 - 0.34
Bar), 0 – 15 psi (0 - 1.03 Bar), and 0 - 30 psi (0 - 2.07 Bar) pressure ranges.
Example, a Peak Combo Sensor with a 0 - 15 psi (0 - 1.03 Bar) pressure transducer
would be specified in psi:
8K-CS4--15-35
.
3
Extension cables can be ordered to specific lengths up to 300 ft. (91m). Note the
desired length (
in feet
) in the
-xxx--
portion of the part number.
Standard
lengths
are 10 ft. (3.0m), 25 ft. (7.6m), 50 ft. (15.2m), 75 ft. (22.8m), 100 ft. (30.5m), 125 ft.
(38.1m), 150 ft. (45.7m), and 200 ft. (61.0m). All other lengths must be custom
ordered.
4
The external power/communications cable and the ground cable included in the
external power grounding kit can be ordered to specific lengths up to 800 ft. (243m).
Note the desired length (
in feet
) in the
–xxx
portion of the part number. Standard
lengths are 10 ft. (3.0m), 25 ft. (7.6m), and 100 ft. (30.5m). All other lengths must
be custom ordered.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...