Configuration and Activation 6-81
If a difference exists between the manual velocity
measurements and the velocity sensor measurements, you can
compensate for this difference by adjusting certain velocity
sensor parameters, particularly Maximum Velocity and
Sensitivity.
Note:
If you change a device parameter, such as an
electronic offset, you must reactivate the monitor.
13.
(
optional
) Click on the
Read
button again to take additional
measurements, if necessary.
14.
Click on the
Close
button once you are finished performing
confirmations for the selected device to exit the
Confirm
Device
dialog.
15.
Repeat steps 2 through 12 for each additional device that
includes a sensor(s) you want to confirm.
Note:
If the location supports a second monitoring point,
remember to confirm the devices assigned to that
monitoring point, as necessary.
16.
If a change has been made to any sensor parameter, reactivate
the monitor. See page 6-72 for more information on
reactivating a monitor.
If you didn’t change any device
parameters, there is no need to reactivate the monitor.
17.
Click on the green
Hangup
button in the
Functions
section to
disconnect from the monitor.
Qstart generates a log entry of the confirmation activity, which
includes the field and monitor readings, the name of the crew,
and any associated comments, and saves it to the local
directory or network. It also generates a log entry for each
user-initiated reading taken by the monitor that includes the
sensor fired, date and time at which the measurement was
taken, current device parameters corresponding to the sensor,
and reading and associated quality. These entries are
available for viewing through the log viewer in Qstart.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...