Maintenance and Troubleshooting 10-33
Troubleshooting
The
flow monitor contains several different components
that perform many different functions. Since a malfunctioning
component increases the risk of losing data, isolating the problem
component is essential to performing troubleshooting activities
efficiently. Minimizing monitor downtime is critical.
Consider the following when trying to isolate the component or
subsystem exhibiting the problem:
Problems affecting only one of the sensor subsystems are
usually caused by one subsystem alone. The problem may exist
in the monitor processor board, sensor (or other input device),
or cabling.
Problems affecting more than one subsystem usually can be
traced to a problem with the processor board, power source, or
communication lines. Problems in one subsystem can create
problems in other subsystems when the power source or
communication lines are faulty.
Problems with communications, clock readings, time stamps,
and data storage intervals usually arise from faulty processor
board components, incorrect information entered on the user's
PC, or low batteries.
Failures occurring outside a connector (i.e., between a
connector and the field input or output device) may arise from
problems with the field unit or component cabling. Failures
occurring on the
inside
(i.e., between a connector and the
printed circuit board) may arise from problems with the
processor board.
Note:
If possible, collect all monitor data prior to
swapping sensors or troubleshooting a monitor to prevent
possible data loss. In addition, remove the monitor from
the manhole before disconnecting cables from the monitor
to avoid possible hazards.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...