5-36
ADS Manual
COMM + EXT PWR Port
COAXIAL Stretch Tape
MONITOR
COMM + EXT PWR CABLE
10-Gauge Ground Wire
to XIO, XBUS, or ExPAC Enclosure
External power/communication cable attached to
COMM + EXT PWR
port
and ground wire secured to bolt on top of monitor
Final Instructions
1.
Verify the following
before
connecting to the power source:
External power cable is connected to both the AC power
source or distribution device (i.e., disconnect, fuse, or
breaker box) and the power supply (
when applicable
)
Power supply (
or appropriate DC power source
) is
connected to the ExPAC
Ground wire is connected to both the XIO/XBUS ground
terminal block/ExPAC (as applicable) and the existing
earth ground
Communication cable is connected to both the monitor and
the ExPAC
Grip fittings on the cable glands are tightened securely and
XIO/XBUS (or other enclosure cover) is closed and
latched
2.
Supply power to the system.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...