10-38 ADS Manual
Communication Problems
The following tables contain general troubleshooting techniques for
wireless communications.
Problem
Monitor does not answer via wireless communication.
Possible
Causes
Signal strength to the modem may be insufficient.
Battery pack may be dead or below minimum voltage
requirement
(7.5 volts - internal).
Wireless network failure.
SIM card is not properly provisioned.
Monitor may have lost communication with network and
cannot re-establish communication.
Connection type may be incorrectly configured in the
monitor.
Antenna may be defective.
Monitor may be defective.
Modem may be defective.
3.3-volt fuse on regulator may have blown.
Leading zeros are included before or within the IP
address.
Содержание Intrinsically-Safe TRITON+
Страница 19: ...1 12 ADS TRITON Manual Control Drawing ...
Страница 25: ...1 18 ADS TRITON Manual First page of the TRITON ATEX Certificate ...
Страница 27: ...1 20 ADS TRITON Manual First page of the TRITON IECEx Certificate of Conformity ...
Страница 29: ...1 22 ADS TRITON Manual CSA Certificate of Compliance Page 1 ...
Страница 30: ...Introduction 1 23 CSA Certificate of Compliance Page 2 ...
Страница 32: ...Introduction 1 25 Sample TRITON Declaration of Conformity Page 2 ...
Страница 34: ...Introduction 1 27 Activate Monitor Qstart software Run Diagnostics and Perform Confirmations Qstart software ...
Страница 49: ...2 12 ADS TRITON Manual ExPAC XBUS ...
Страница 159: ...External Power 5 9 Power supply firmly secured to the DIN rail Front view of power supply mounted to DIN rail ...
Страница 171: ...External Power 5 21 POWER SUPPLY DC OUTPUT TERMINAL CONNECTIONS Wires exiting DC output terminal on power supply ...
Страница 231: ...6 44 ADS TRITON Manual Editing the Smart Ultrasonic Depth Sensor Device Edit Smart Depth 1 Parameters dialog ...