Action
Screws: 3HAB3409-207 (M3x8).
Refit the cover on the upper arm housing.
7
Tightening torque: 1.5 Nm.
xx1300000456
Note
Only use specified screws, never
replace them with other screws.
For robots with protection type Clean Room:
8
For robots with food grade lubrication:
For robots with protection type Hygienic:
Clean, seal and paint the joints that have been
opened. See
Cut the paint or surface on the robot
before replacing parts on page 158
Note
After all repair work, wipe the robot free from
particles with spirit on a lint free cloth.
The signal lamp is now ready for use and is lit in
MOTORS ON mode.