Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
2
xx1400001205
Remove the protection cover from the housing.
3
Clean the location surfaces on the housing and
the calibration tool surfaces to make sure there
is no paint or burrs on these surfaces.
4
Screws: M4x16.
xx1400001208
Fit the calibration block to the tubular.
5
Locate the calibration tool by the location surface
on the housing.
Tip
Press down slightly on the calibration tool to make
sure the tool attaches the location surface tightly.
6
Continues on next page
Product manual - IRB 1200
855
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.6.6 Manual calibration method - calibrating axis 4
Continued