Performing the fine calibration procedure
Note
Action
WARNING
Do not fine calibrate the robot without special
equipment used for axis calibration! It would
cause an unsatisfied accuracy in the robot
movement.
1
Choose fine calibration from Calib menu
2
On the
ABB
menu, tap
Calibration
.
All mechanical units connected to the system are
shown along with their calibration status.
Tap to select the mechanical unit and then tap
Calib. Parameters
.
en0400001127
3
Tap
Fine Calibration...
.
4
A dialog box is displayed, urging you to use ex-
ternal equipment to perform the actual calibration.
Make sure all necessary calibration equipment is
fitted for the axis to be calibrated.
A dialog box is displayed, warning that updating
the revolution counters may change programmed
robot positions:
•
Tap
Yes
to proceed.
•
Tap
No
to cancel.
Select the check-box for the current axis/axes to
be calibrated.
5
Continues on next page
Product manual - IRB 1200
857
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.6.6 Manual calibration method - calibrating axis 4
Continued