Note
Action
Gasket on top swing cover
For robots with protection class IP67
9
3HAC056696-001 (not Hygienic robots) /
3HAC080698-001 (Hygienic robots)
xx1400000425
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the gasket.
Replace if damaged.
Cover on top of swing: 3HAC059679-001
Refit the swing top cover with the screws.
10
Cover on top of swing, Clean Room
Replace if damaged.
Cover on top of swing, food grade lubrica-
tion
Cover on top of swing, Hygienic
: 3HAC056133-001
Screws: 3HAB3409-209 (M3x20).
Tightening torque: 1.5 Nm.
xx1300000467
Note
Only use specified screws, never replace
them with other screws.