![ABB IRB 1200 Скачать руководство пользователя страница 145](http://html.mh-extra.com/html/abb/irb-1200/irb-1200_product-manual_5020145.webp)
Note
Art. no.
Spare part
Used with protection type Hy-
gienic.
3HAC078798-001
Gasket, axis 6, Hygienic
Replace if damaged.
Used with protection type Hy-
gienic.
3HAC079688-001
Seal ring unit
Replace if damaged.
The seal ring unit is wear part.
Used with protection type Hy-
gienic.
3HAC034160-003
Sealing washer
Replace if damaged.
Required tools and equipment
Note
Article number
Equipment, etc.
Content is defined in section
.
-
Standard toolkit
Used with robots in protection type
Hygienic
Used for loosen and tighten the seal
ring unit on tool flange of the Hygienic
robots.
3HAC079686-001
Flange tightening tool
Used with robots in protection type
Hygienic
3HAC079684-001
Guide pin for stainless shaft
on tool flange
Required consumables
Note
Art. no.
Consumable
Molykote P1900
3HAC070875-001
Grease
For robots with protection type
Hygienic
CAUTION
Always cut the paint with a knife and grind the paint edge when disassembling
parts. See
Cut the paint or surface on the robot before replacing parts on page 158
.
Replacing the sealing parts on tool flange of Hygienic robots
Note
Action
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
1
Continues on next page
Product manual - IRB 1200
145
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.4.2 Replacing the sealing set on tool flange of Hygienic robots
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......