Note
Action
Gasket on EIB/SMB cover:
3HAC056728-001 (not Hygienic
robots) / 3HAC080706-001 (Hygien-
ic robots)
xx1400000475
For robots with protection class IP67
For robots with protection type Foundry Plus
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the EIB/SMB cover gasket.
Replace if damaged.
3
xx1300002428
Valid for IRB 1200 (no type specified) and IRB
1200 Type A
Connect the connectors to the EIB unit.
•
R1.ME1-3
•
R1.ME4-6
•
R2.EIB
WARNING
Make sure not to mix the R2.EIB and R2.ME2.
Axis 2 may be severely damaged. See the labels
on the connectors for correct connection.
4
Valid for IRB 1200 (no type specified) and IRB
1200 Type A
5
Connect the lugs to the EIB/SMB cover.
xx1700000005
Valid for IRB 1200 Type B
Connect the connectors to the SMB unit.
•
R1.ME1,2,4,5
•
R1.ME3,6
•
R2.SMB
WARNING
Make sure not to mix the R2.SMB and R2.ME2.
Axis 2 may be severely damaged. See the labels
on the connectors for correct connection.
6
Continues on next page
358
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.1 Replacing the lower arm
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......