Note
Action
Water temperature: ambient
Rinse thoroughly with water to remove the disin-
fection.
11
Wipe the surface dry with lint free cloth.
12
If user tools are removed from the robot flange
before the cleaning, then, after cleaning,
•
Make sure no residues left on the tool
flange or screw holes before reinstall the
tools or any other accessories to the flange.
13
Wipe down procedure
Note
Action
Before cleaning,
•
Make sure no spraying or ejecting of any
detergents, disinfectants and water to the
robot surfaces during the cleaning.
1
Use the lint free cloth to remove soils or any other
contaminant from the to-be-cleaned surfaces.
2
Make sure no visible residues left.
Disinfectant: DRYSAN
TM
DUO,
concentration (v/v) 100 %
Spray disinfectant DRYSAN
TM
DUO on robot
surfaces.
3
Wait 2-3 minutes for disinfectant volatilization and
then wipe the robot with lint free cloth.
4
Product manual - IRB 1200
155
3HAC046983-001 Revision: S