Note
Article number
Equipment, etc.
Includes calibration tools, pins and at-
tachment screws for manual calibration
method.
i
3HAC051256-001
Calibration toolkit, manual
calibration
Content is defined in section
.
-
Standard toolkit
i
The robot is calibrated by either manual calibration or Axis Calibration at factory. Always use the
same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, manual calibration is used as default.
Required consumables
Note
Article number
Equipment
-
Cable straps
Used for lubrication of cable con-
tact areas.
3HAC042536-001
Grease
Used for lubrication of cable con-
tact areas for robots with food
grade lubrication and robots in
protection type Hygienic.
3HAC029132-001
Grease
Loctite 243
3HAB7116-1
Locking liquid
Loctite 7063
-
Cleaning agent
Loctite 574
12340011-116
Flange sealing
For robots with protection type
Clean Room.
For robots with food grade lubric-
ation.
Sikaflex 521FC
3HAC026759-001
Sealant
For robots with protection type
Clean Room.
For robots with food grade lubric-
ation.
For robots with protection class
IP67.
For robots with protection type
Foundry Plus.
Trans Clear
3HAC073510-001
Sealant
For robots with protection type
Hygienic
Continues on next page
Product manual - IRB 1200
175
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.1 Replacing the main cable package
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......