Note
Action
xx1300002433
Pull out the cabling and then remove the axis-2
motor bracket from the cable package by remov-
ing the screws.
CAUTION
Do not loosen the cable clamp screw! There is a
risk of rearrangement of the cable layout which
would result in shortened lifetime of the cable
harness.
11
xx1300002434
Disconnect the motor connectors.
•
R2.ME2
•
R2.MP2
12
xx1300002435
Loosen the cable housing from the swing by re-
moving the screws. Leave it hanging on the cable
package.
13
Continues on next page
Product manual - IRB 1200
191
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.1 Replacing the main cable package
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......