![ABB IRB 1200 Скачать руководство пользователя страница 738](http://html.mh-extra.com/html/abb/irb-1200/irb-1200_product-manual_5020738.webp)
Concluding procedure
Note
Action
Housing cover gasket (IRB 1200-7/0.7 ):
3HAC056698-001 (not Hygienic robots) /
3HAC080700-001 (Hygienic robots)
For robots with protection class IP67
For robots with protection type Foundry
Plus
1
Housing cover gasket (IRB 1200-5/0.9 ):
3HAC056697-001 (not Hygienic robots) /
3HAC080699-001 (Hygienic robots)
xx1400000477
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the gasket.
Replace if damaged.
Screws: 3HAB3409-207 (M3x8).
Refit the upper arm housing cover with the
screws.
2
Tightening torque: 1.5 Nm.
xx1300000456
Note
Only use specified screws, never replace
them with other screws.
Continues on next page
738
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.6.5 Replacing the axis-4 motor with pulley
Continued