Note
Action
xx1300002427
Remove the connector cover attachment screws
on the lower arm and carefully open the cover.
CAUTION
Clean cover from metal residues before opening.
Metal residues can cause shortage on the boards
which can result in hazardous failures.
CAUTION
Be aware of the cabling that is attached to the
cover!
4
xx1400000812
Valid for IRB 1200 (no type specified) and IRB
1200 Type A
Disconnect the connectors on the EIB unit.
•
R1.ME1-3
•
R1.ME4-6
•
R2.EIB
5
xx1700000004
Valid for IRB 1200 Type B
Loose the connector screws.
6
Continues on next page
Product manual - IRB 1200
137
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.4.1 Replacing the battery pack
Continued