Note
Action
Gasket on lower arm cable housing:
3HAC044895-001 (not Hygienic robots) /
3HAC080696-001 (Hygienic robots)
xx1400000414
For robots with protection class IP67
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the cable housing gasket.
Replace if damaged.
9
M2 variseal sealing: 3HAC044641-006
For robots with protection class IP67
10
Radial sealing: 3HAC024865-001
xx1400000473
For robots with protection type Foundry
Plus
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Check the axis-3 radial sealing and the M2
variseal sealing in the cable housing.
Replace if damaged.
CAUTION
Do not fit M2 variseal sealing on Clean
Room, food grade lubrication and Hygienic
robots.
Note
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Apply a little grease to the sealing when
replacing the radial sealing and wipe clean
after the replacement.
Replacement is detailed in
axis-3 radial sealing and sealing ring on
page 418
Continues on next page
346
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.4.1 Replacing the lower arm
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......