Note
Action
xx1400000020
Remove the axis-2 sealing ring by removing the
screws.
14
Pull out the cable package from the lower arm.
Tip
There is a groove on the lower arm casting that
simplifies cable passage, if needed. Its position
can easily be felt by hand.
15
xx1400000023
Loosen the plastic plate from the cable housing
in order to facilitate continued removal of the cable
package .
16
Fitting lifting equipment to the upper and lower arm
Note
Action
CAUTION
The lower and upper arms together weigh 30 kg.
All lifting accessories used must be sized accord-
ingly!
1
Roundsling, 2 m
Fit lifting slings to the upper and lower arm.
2
Removing the lower arm
Note
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
Continues on next page
592
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the swing spare parts (swing, axis-2 radial sealing)
Continued