![ABB IRB 1200 Скачать руководство пользователя страница 514](http://html.mh-extra.com/html/abb/irb-1200/irb-1200_product-manual_5020514.webp)
Note
Action
xx1400000680
Loosen the robot from the foundation by
removing the foundation attachment
screws and put the robot on its side.
7
Separating the arm system from base
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
xx1300000467
Remove the swing top cover by removing the
screws.
Tip
Fit M4 screws in the cover holes to pull out the
cover more easily. Only tighten the screws lightly
in order not to damage the threads.
3
Continues on next page