![ABB IRB 1200 Скачать руководство пользователя страница 287](http://html.mh-extra.com/html/abb/irb-1200/irb-1200_product-manual_5020287.webp)
Note
Action
Tightening torque: 1.5 Nm.
Refit the tubular cable housing with the screws.
3
Tubular cable housing:
3HAC059695-001
Tubular cable housing, Clean
Room
Tubular cable housing, food grade
lubrication
: 3HAC056143-001
Tubular cable housing, Hygienic:
3HAC079692-001
xx1300002392
Refitting the connector plate
Note
Action
For robots with protection type Clean
Room
1
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and
wipe the parts free from particles with
spirit on a lint free.
Tightening torque: 0.3 Nm.
xx1400001401
Refit the connector plate and secure with
the M3 screws.
2
Continues on next page
Product manual - IRB 1200
287
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the axis-5 FPC unit
Continued