Note
Action
xx1400000455
Remove the axis-1 sealing ring from the swing
and carefully run the cabling out from the swing.
6
Removing the axis-2 radial sealing (IP67 and Foundry Plus)
Use this procedure if replacing the axis-2 radial sealing.
The sealing is only used for robots with protection class IP67 and with protection
type Foundry Plus.
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx1400000450
Remove the axis-2 radial sealing from the cable
housing.
2
Continues on next page
596
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.2 Replacing the swing spare parts (swing, axis-2 radial sealing)
Continued