Note
Action
Tightening torque: 0.3 Nm.
xx1400000776
Move the protection sleeve from the old base to
the new.
3
Tightening torque: 12 Nm.
xx1400000392
Move the axis-1 mechanical stop set from the old
base to the new.
Replace if damaged.
4
Refitting the axis-1 radial sealing and M2 variseal sealing
Note
Action
For robots with protection type Clean
Room
1
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and
wipe the parts free from particles with
spirit on a lint free.
For robots with protection type Clean
Room
2
Apply a little grease to the sealing when
replacing the radial sealing and wipe clean
after the replacement.
Continues on next page
528
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the base spare parts (base, axis-1 radial sealing, protection sleeve)
Continued