Note
Action
Tap
Calibrate
.
6
A dialog box is displayed, warning that calibration
of the selected axes will be changed, which cannot
be undone:
•
Tap
Calibrate
to proceed.
•
Tap
Cancel
to cancel.
Tapping
Calibrate
results in briefly displaying a
dialog box, announcing that the calibration pro-
cess has started.
The axis is calibrated and the system returns to
the list of available mechanical units.
Checking and finalizing the calibration
Note
Action
Release the brakes and manually rotate the axis
to apart the calibration pins from each other. This
is done to avoid damage on the pins if incorrect
operation should occur during next step of jog-
ging.
1
Remove the calibration tool of axes 4, 5, and 6
from the tubular.
2
Remove the axis-4 calibration tool from the
housing.
3
Jog axis 4 to zero degree using the FlexPendant.
4
xx1400001095
Check that the synchronization marks on axis 4
are aligned with eachother.
Are they aligned within the tolerances?
•
If yes, the calibration is verified OK.
•
If no, redo the fine calibration procedure.
5
xx1400001205
Refit the protection cover to the housing.
6
Continues on next page
858
Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.6.6 Manual calibration method - calibrating axis 4
Continued
Содержание IRB 1200
Страница 1: ...ROBOTICS Product manual IRB 1200 ...
Страница 2: ...Trace back information Workspace 21D version a15 Checked in 2021 12 16 Skribenta version 5 4 005 ...
Страница 156: ...This page is intentionally left blank ...
Страница 896: ...This page is intentionally left blank ...
Страница 898: ...This page is intentionally left blank ...
Страница 905: ......