![ABB IRB 1200 Скачать руководство пользователя страница 527](http://html.mh-extra.com/html/abb/irb-1200/irb-1200_product-manual_5020527.webp)
Note
Action
xx1400000780
Remove the M2 variseal sealing.
The M2 variseal sealing is only installed on
base version 3HAC049628-001. See
part versions for the base on IP40/IP67 ro-
bots on page 874
.
4
xx1400000270
Remove the radial sealing.
5
Replacing the base
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
CAUTION
For robots with protection type Clean Room
For robots with food grade lubrication
For robots with protection type Hygienic
Always cut the paint with a knife and grind the
paint edge when disassembling parts of the robot!
See
Cut the paint or surface on the robot before
2
Continues on next page
Product manual - IRB 1200
527
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
4 Repair
4.5.1 Replacing the base spare parts (base, axis-1 radial sealing, protection sleeve)
Continued