Disconnecting the axis-4 motor connectors
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
xx2000001542
Remove the connector plate.
CAUTION
Be aware of the cablings that are attached to the
connector plate! The connector plate cannot be
removed completely until the connectors are re-
move from the plate.
2
xx2000001543
Cut the cable strap.
Note
The motor cablings have another strap fixed. Al-
ways cut the strap that fixes the cable package
to the plate.
3
xx2000001544
Disconnect the connectors.
•
MP4
•
FB4
Tip
Take photos of the connector and cable position
before disconnecting them, to have as a reference
when reconnecting.
4
xx2000001545
Snap loose and remove the male head of the
connectors from the connector plate.
5
Continues on next page
Product manual - CRB 1300
521
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.4 Replacing the axis-4 motor
Continued