Note
Action
xx2000001505
Reconnect the battery cable.
3
Reconnecting the SMB connectors
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
1
Tightening torque: 0.3 Nm
Reconnect the connectors.
•
SMB.J1
•
SMB.J2
•
R2.SMB
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
xx2000001504
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Refit the SMB cover to the base.
4
Tightening torque: 2.6 Nm
xx2000001503
Continues on next page
192
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
4 Maintenance
4.6.1 Replacing the battery pack
Continued