7.7 Communication failure between PLC and controller
Description
The OmniCore controller and PLC are configured with all parameters correctly set.
However, the communication between the OmniCore controller and PLC still fails.
This issue may occur when the PROFIsafe-based laser scanner(s) is connected.
Consequence
The safety configurations do not take effect.
Possible causes
During configuration of communication between the OmniCore controller and PLC,
the PROFIsafe device information must be configured on the OmniCore controller’s
side first. Otherwise, the configured signals will not be saved in the safety module
in the OmniCore controller.
Recommended actions
1 Open the RobotStudio.
2 In the
Controller
tab page, choose
Visual SafeMove
from
Safety
in the
Configuration
group.
3 Check the Safe I/O configurations.
For robots running RobotWare 7.5 or earlier, the following signals can be
observed.
xx2100000511
Continues on next page
698
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
7 Troubleshooting
7.7 Communication failure between PLC and controller
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......