Configuring button functions
The button-type lead-through device provides two buttons, flat and raised, for users
to configure specific functions according to application requirements. The button
function configuration is only available to robots:
•
operating in RobotWare version 7.7 or later, and,
•
installing with the Collaborative Speed Control add-in in version 1.1 or later
Use the following procedure to configure the button functions:
1 Tap
Settings
on the home page of the FlexPendant.
2 Tap
Lead-through Device
.
3 Tap
Configurable buttons
on the left pane.
4 Select desired function from the drop-down list for the required button.
•
Add a move location
: a
Move
block will be added to Wizard app. This
is the default configuration for the flat button.
•
Linear / Reorient
: the lead-through mode will be changed between
linear and reorient. This is the default configuration for the raised button.
•
Lock Z
: the movement along the Z direction will be locked.
•
Lock XY
: the movement along the X and Y directions will be locked.
After selection, configured action takes effect when pressing the button.
114
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.3 Lead-through
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......