![ABB CRB 1300 Скачать руководство пользователя страница 244](http://html.mh-extra.com/html/abb/crb-1300/crb-1300_product-manual_3045544244.webp)
Note
Action
xx2000001574
Reconnect the earth cable.
2
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Valid for cabling with bottom interface (option
3309-1)
3
Tightening torque: 2.6 Nm
Refit the base rear cover.
xx2000001573
Reconnecting the SMB connectors
Note
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 49
1
Tightening torque: 0.3 Nm
Reconnect the connectors.
•
SMB.J1
•
SMB.J2
•
R2.SMB
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
xx2000001504
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
244
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......