Configuring SafeMove
To enable SafeMove, perform the following procedure:
1 Log in the FlexPendant.
Make sure the user logged in have access grants to lock safety controller
configurations, safety services and software synchronization.
2 Tap
SafeMove
on the home page.
3 Tap
Load
in the pop-up message box to confirm loading of template SafeMove
configuration files.
The controller restarts.
4 After the controller is restarted, tap
Settings
on the home page.
5 Tap
Safety Controller
.
6 Tap
Synchronization
in the left pane.
7 Jog the robot to match the
Actual Positions
values with the
Sync Positions
values.
Make sure the values are the same.
8 Tap
Synchronize
.
154
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.5.6 Configuration of two SafetyIO-base laser scanners (RobotWare 7.6 or later)
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......