5 In the displayed
Safe IO Configuration
window, go to the signal
ISH_UserMODE_bNot_IntemitCollab
in the global signal list and set the
value to
1
.
xx2200000436
6 Apply the configuration to the controller by clicking
Write to Controller
in
the
Controller
group in the
Configuration
category.
If the SpeedHandling function requires to be reactivated after deactivation, make
sure:
•
the signal ISH_UserMODE_bNot_IntemitCollab in SafeMove configuration
is set to
0
, and,
•
the function ISH_b_FunctionlityIsUsed in RAPID program is set to TRUE.
Changing the speed limit when WarningArea is triggered
When users enter the warning area, the robot speed is limited to 250 mm/sec by
default. Use the following procedure to change the speed limit based on risk
assessment of the final application:
1 In RobotStudio, open the RAPID program InternalSpeedHandling_User in
task T_ROB1.
2 Navigate to the function ISH_n_Speed_In_WarningArea_mm_s and set its
value from default 250 to any required value.
xx2200000437
3 Save the change and apply to the controller.
The speed limit can also be changed in SafeMove configurations using the following
procedure:
1 Open the RobotStudio.
2 Log in the controller using the Admin account and request the write access.
Continues on next page
Product manual - CRB 1300
161
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.7 Use cases of safety configurations
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......