![ABB CRB 1300 Скачать руководство пользователя страница 276](http://html.mh-extra.com/html/abb/crb-1300/crb-1300_product-manual_3045544276.webp)
Refitting the base covers
Note
Action
Gasket for base adapter:
3HAC067818-001
For robots with protection class IP67 (option
3350-670)
1
xx2000002510
Valid for cabling with rear interface
Check the gasket.
Replace if damaged.
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (8 pcs)
Valid for cabling with rear interface
Refit the base bottom cover together with the base
adapter.
2
Tightening torque: 2.6 Nm
xx2000001642
Securing the base to the foundation
Note
Action
Attachment screws: M16x50, qual-
ity: 8.8.
Secure the base to the foundation with the attach-
ment screws and washers.
1
Washers: 17 x 30 x 3, steel hard-
ness class 200HV.
Tightening Torque: 150 Nm±10
Nm.
Refitting the axis-1 mechanical stops
Note
Action
Screw: M4x25 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Refit the axis-1 mechanical stop fixed block.
1
Tightening torque: 3.8 Nm
xx2000001693
Continues on next page
276
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.4.1 Replacing the base
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......