Note
Action
Screw: M4x10 12.9 Lafre
2C2B/FC6.9 (6 pcs)
Refit the SMB cover to the base.
4
Tightening torque: 2.6 Nm
xx2000001503
Refitting the connector interface plate
Note
Action
Gasket for base cover:
3HAC067819-001
For robots with protection class IP67 (option
3350-670)
1
xx2000002514
Check the gasket.
Replace if damaged.
Seal bolt: 3HAC032050-001
For robots with protection class IP67 (option
3350-670)
2
xx2000002515
Check the seal bolt.
Replace if damaged.
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
3
Continues on next page
Product manual - CRB 1300
245
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued