Note
Action
Tightening torque: 3.3 Nm
Secure the motor with the screws.
4
xx2000001614
Release the support to the upper arm.
5
Reconnecting the axis-3 motor connectors
Note
Action
xx2000001621
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001620
Route and secure the cabling with a cable strap.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
xx2000001619
Reconnect the connectors.
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Continues on next page
Product manual - CRB 1300
515
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-3 motor
Continued