Note
Action
Gasket for lamp unit cover:
3HAC082935-001
For robots with protection class IP67 (option
3350-670)
2
xx2200001004
Check the gasket.
Replace if damaged.
Lamp unit cover: 3HAC082320-001
Refit the lamp unit cover.
3
Screw: M3x8 12.9 Lafre
2C2B/FC6.9 (4 pcs)
Tightening torque: 0.6 Nm
xx2200001002
Reconnecting the air hoses and Ethernet cabling (if equipped)
Note
Action
xx2000001539
Reconnect the air hoses.
Note
See the number markings on the air hoses for
help to find the corresponding air hoses.
1
xx2200001001
For robots with Ethernet cabling
Access the connector from the process hub and
reconnect the connector.
•
J1.C2
Tip
See the number markings on the connectors for
help to find the corresponding connector.
2
Continues on next page
Product manual - CRB 1300
415
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the housing and extender unit
Continued