![ABB CRB 1300 Скачать руководство пользователя страница 310](http://html.mh-extra.com/html/abb/crb-1300/crb-1300_product-manual_3045544310.webp)
Reconnecting the axis-2 and -3 motor connectors
Note
Action
xx2000001551
Insert the male header of the motor connectors
to the connector plate.
1
xx2000001549
Route and secure the cabling with cable straps.
CAUTION
Correct cable routing is highly important.
If the cables are routed and secured incorrectly
the cables can be damaged.
2
xx2000001550
Reconnect the connectors.
•
FB2
•
MP2
•
FB3
•
MP3
Tip
See the number markings on the connectors for
help to find the corresponding connector.
3
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate to the lower arm.
4
Tightening torque: 2.6 Nm
xx2000001548
Continues on next page
310
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the swing
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......