Note
Action
WARNING
When separating the motor from the gearbox,
there may be pressure present in the gearbox,
causing lubricant to spray from the opening. Be-
fore proceeding, please read the safety informa-
tion in the section
.
2
CAUTION
Removing motors will release axes. This means
the axes can fall down.
Make sure axes are well supported before remov-
ing motors.
3
xx2000001624
Cut the cable strap.
4
xx2000001625
Remove the cable bracket.
5
xx2000001627
Access the screws and washers securing the axis-
2 motor from the swing support.
6
Continues on next page
Product manual - CRB 1300
345
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the lower arm
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......