Create variables.
Example address
i
Type
Name
%I3.0
Bool
ProtectingTrigger
%I4.1
Bool
WarningTrigger
%Q68.0
Bool
ProtectingArea
%Q68.1
Bool
WarningArea
%Q68.2
Bool
SafetyCommunicationEnable
%Q3.0
Bool
ActivateScanner
i
%I3.
X
and %I4.
X
are the addresses of the laser scanner; %Q68.
X
is the address of the
OmniCore controller.
%Q3.0 is for activating the monitoring cases of the laser scanner.
•
Check the communication between the PLC and controller is well and activate
the laser scanner; set up the communication between the laser scanner, PLC
and OmniCore controller.
Configuring SafeMove
To enable SafeMove, perform the following procedure:
1 Log in the FlexPendant.
Make sure the user logged in have access grants to lock safety controller
configurations, safety services and software synchronization.
2 Tap
SafeMove
on the home page.
3 Tap
Load
in the pop-up message box to confirm loading of template SafeMove
configuration files.
The controller restarts.
4 After the controller is restarted, tap
Settings
on the home page.
5 Tap
Safety Controller
.
6 Tap
Synchronization
in the left pane.
7 Jog the robot to match the
Actual Positions
values with the
Sync Positions
values.
Make sure the values are the same.
8 Tap
Synchronize
.
132
Product manual - CRB 1300
3HAC083111-001 Revision: B
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.5.1 Configuration of one PROFIsafe-based laser scanner (RobotWare 7.6 or later and PLC acting
as Master)
Continued
Содержание CRB 1300
Страница 1: ...ROBOTICS Product manual CRB 1300 ...
Страница 2: ...Trace back information Workspace 23A version a14 Checked in 2023 03 20 Skribenta version 5 5 019 ...
Страница 50: ...This page is intentionally left blank ...
Страница 662: ...This page is intentionally left blank ...
Страница 690: ...This page is intentionally left blank ...
Страница 704: ...This page is intentionally left blank ...
Страница 720: ...This page is intentionally left blank ...
Страница 725: ......