88 Program features
When adaptive voltage limit is disabled in parameter
:
Settings and diagnostics
Parameters
),
(page
) and
(page
Events: -
DC voltage level [V]
95.01 Supply Voltage
See
.
Supply voltage
range [V]
180…415
Supply voltage
range [V]
440…480
Automatic /
Not selected
if
< 456AC
> 456AC
Overvoltage fault limit
842
842
842
Overvoltage control limit
779
779
779
Overvoltage warning limit
745
745
745
Undervoltage warning limit
0.85×1.35×180 = 436
0.85×1.35×440 =
504
0.85×1.35×180
= 436
0.85×1.35×440
= 505
Undervoltage control limit
0.78×1.35×180 =400
0.78×1.35×440 =
463
0.78×1.35×180
= 400
0.78×1.35×440
= 463
Charging relay closing limit
0.78×1.35×180 = 400
0.78×1.35×440 =
463
0.78×1.41×par
value
1)
Charging relay opening
limit
0.73×1.41×par
value
1)
0.78×1.41 ×par
value
1)
0.73×1.41×par
value
1)
DC voltage at upper bound
of supply voltage range
(
U
DCmax
)
560
648
DC voltage at lower bound
of supply voltage range
(
U
DCmin
)
513
594
Charging
activation/standby limit
0.73×1.41×par
value
1)
0.73×1.41×par
value
1)
0.73×1.41×par
value
1)
Undervoltage fault limit
3)
0.45×1.41×par
value
1)
0.45×1.41×par
value
1)
0.45×1.41×par
value
1)
1)
If parameter
is set to
Automatic / not selected
and
is set to
Enable
, the value of parameter
is used,
2)
otherwise the
lower limit of the range selected with parameter
is used.
3)
The drive trips on the undervoltage fault when parameter
(
) elapses or the value
of parameter
is 0. In that case the standby limit is used as the undervoltage trip level. The
undervoltage fault occurs only if the drive is modulating when the DC voltage drops below the
undervoltage trip level.
ACS180 FW.book Page 88 Tuesday, March 9, 2021 2:25 PM