Parameters 165
Sub (ref1 - ref2)
The subtraction ([
] - [
]) of the reference sources is used as speed
reference 1.
2
Mul (ref1 × ref2)
The multiplication of the reference sources is used as
speed reference 1.
3
Min (ref1, ref2)
The smaller of the reference sources is used as speed
reference 1.
4
Max (ref1, ref2)
The greater of the reference sources is used as speed
reference 1.
5
Determines how constant speeds are selected, and
whether the rotation direction signal is considered or not
when applying a constant speed.
0b0001
0b0000...ob1111
Constant speed configuration word.
1 = 1
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Information
0
Constant speed
mode
1 = Packed: 7 constant speeds are selectable using the three sources
defined by parameters
and
0 = Separate: Constant speeds 1, 2 and 3 are separately activated by
the sources defined by parameters
,
and
respectively.
In case of conflict, the constant speed with the smaller number takes
priority.
1
Direction
enable
1 = Start dir: To determine running direction for a constant speed, the
sign of the constant speed setting (parameters
) is
multiplied by the direction signal (forward: +1, reverse: -1). This
effectively allows the drive to have 14 (7 forward, 7 reverse) constant
speeds if all values in
are positive.
WARNING!
If the direction signal is reverse and the active
constant speed is negative, the drive will run in the forward
direction.
0 = According to Par: The running direction for the constant frequency is
determined by the sign of the constant speed setting (parameters
…
2
Speed step
1 = Speed step enable; 0 = Speed step disable
3…15
Reserved
ACS180 FW.book Page 165 Tuesday, March 9, 2021 2:25 PM