252 Parameters
43
Configuration of mechanical brake control.
Displays the mechanical brake control status word.
This parameter is read-only.
0000h
0000h…FFFFh
Mechanical brake control status word.
1 = 1
Activates/deactivates (or selects a source that
activates/deactivates) the mechanical brake control logic.
0 = Brake control inactive
1 = Brake control active
Not selected
The brake control function is disabled.
0
Selected
The brake control function is enabled.
1
DI1
Digital input DI1 (
, bit 0).
2
DI2
Digital input DI2 (
, bit 1).
3
DI3
Digital input DI3 (
, bit 2).
4
DI4
Digital input DI4 (
, bit 3).
5
DI5
Digital input DI5 (
, bit 4).
6
Supervision 1
Bit 0 of
24
Supervision 2
Bit 1 of
25
Supervision 3
Bit 2 of
26
Supervision 4
Bit 3 of
27
Supervision 5
Bit 4 of
28
Supervision 6
Bit 5 of
29
-
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Information
0
Open command
Close/open command to brake actuator (0 = close, 1 = open).
Connect this bit to desired output.
1
Opening torque
request
1 = Opening torque requested from drive logic
2
Hold stopped
request
1 = Hold requested from drive logic
3
Ramp to stopped
1 = Ramping down to zero speed requested from drive logic
4
Enabled
1 = Brake control is enabled
5
Closed
1 = Brake control logic in
state
6
Opening
1 = Brake control logic in
state
7
Open
1 = Brake control logic in
state
8
Closing
1 = Brake control logic in
state
9…15
Reserved