Managing System Alarms
207
PathBuilder S700 Alarm
Messages
This section lists the alarm messages, meanings of the alarm messages, and
troubleshooting tips for the major errors reported from each of the PathBuilder
S700 interfaces. It contains the following subsections:
n
MCPU and STX Module (System) Alarms
n
Alarms Common to Several Modules
n
DS1/E1 UNI Module Alarms
n
DSX-1/E1 CBR Module Alarms
n
QSIM/FAM Alarms
MCPU and STX Module (System) Alarms
Table 41 describes the Critical and Major Alarms associated with the CPU Module.
Table 41
MCPU and STX Module (System) Alarms
Alarm
Meaning
Troubleshooting Steps
A card is removed
from a card slot
A card has been removed from
the shelf.
Install the card.
Alarms Cleared
Current alarms have been
cleared by user.
Information only.
ALM Dest Slot
Overrun
The destination slot has failed
and is not taking cells from the
STX card.
Find and replace the defective card.
ALM Ext SRAM
Parity Er
STX hardware failure.
Replace the STX card.
ALM Ingress FIFO
Overflow
STX hardware failure.
Replace the STX card.
ALM Ingress Sync
Error
STX hardware failure.
Replace the STX card.
ALM Ingress VCI
Out of Range
The cells received by the STX
have a VCI that is out of range.
Verify the integrity of the incoming
traffic, checking to see if the traffic
matches the assigned VPIs. Replace the
port card. Replace the STX card.
ALM Ingress VPI
Over 255
The cells received by the STX
have an improper VPI value.
Verify the integrity of the incoming
traffic, checking to see if the traffic
matches the assigned VPIs. Replace the
port card. Replace the STX card.
ALM Parity Error
Egress/QCX
STX hardware failure
Replace the STX card.
ALM Parity Error
Ingress/CB
STX hardware failure
Replace the STX card.
BITS reference clock
failure
Enabled when the BITS clock is
selected as the timing source
but has failed.
Check the BITs clock source for other
alarms.
Bus A Parity Error
STX hardware failure.
Replace the STX card.
Bus B Parity Error
STX hardware failure.
Replace the STX card.
Bus C Parity Error
STX hardware failure.
Replace the STX card.
Bus D Parity Error
STX hardware failure.
Replace the STX card.
Bus E Parity Error
STX hardware failure.
Replace the STX card.
Bus F Parity Error
STX hardware failure.
Replace the STX card.
(continued)
Содержание 3C63400-3AC-C - PathBuilder S700 Switch
Страница 14: ...xiv CHAPTER SUPPLEMENTARY REGULATORY INFORMATION ...
Страница 18: ...4 ABOUT THIS GUIDE ...
Страница 28: ...14 CHAPTER 1 SYSTEM DESCRIPTION ...
Страница 88: ...74 CHAPTER 3 GETTING STARTED ...
Страница 260: ...246 CHAPTER 6 PATHBUILDER S700 DIAGNOSTICS AND PERFORMANCE MONITORING ...
Страница 270: ...256 INDEX ...